Profibus ET200X + ECOFAST
Applications :
Construction :
-
Type/Area of Application Drag Chain Applications Mobile Use Cable Construction 1x2x0.65 mm + 3x1x0.75 mm2 (stranded) 1x2x0.65 mm + 4x1x1.5 mm2(stranded) Inner Conductor Diameter 1 Copper, bare (AWG 22/19) Copper, bare (AWG 24/19) Inner Conductor Diameter 2 Copper, bare (AWG 18/24) Copper, bare (AWG 18/84) Conductor Insulation 1 Foam-skin-PE Foam-skin-PE Conductor Insulation 2 PVC TPM Conductor Colors 1 red, green red, green Conductor Colors 2 black, blue, green-yellow back, back, back, back Stranding Element Double Conductor 2 conductors + 2 fillers stranded together Wrapping Polyester foil over stranded bundle Polyester foil over stranded bundle Shielding Foil + Braid Foil + Braid Overall wrapping Polyester foil - Outer Jacket Material PUR TPU Outer Diameter 9.5 mm ± 0.5 mm 11.0 mm ± 0.3 mm Outer Jacket Color Green Violet
Electrical Data :
-
CharacteristicImpedance@3-20Hz 150 Ω ± 10 Ω 150 Ω ± 10 Ω Conductor Resistance 84.0 Ohm/km max. 89.9 Ohm/km max. Insulation Resistance 1.00 GOhm x km min. 1.00 GOhm x km min. Mutual Capacitance@1KHz 30.0 nF/km nom. 30.0 nF/km nom. Working Voltage Max: 250 V Test Voltage 1.5 kV 1.5 kV Attenuation 9.6 kHz < 3.0 dB/km 9.6 kHz < 3.0 dB/km 38.4 kHz < 5.0 dB/km 38.4 kHz < 5.0 dB/km 4.0 MHz < 25.0 dB/km 4.0 MHz < 30.0 dB/km 16.0 MHz < 52.0 dB/km 16.0 MHz < 60.0 dB/km
Technical Data :
-
Weight approximately 105.0kg/km approximately 159.0kg/km Min. Bending Radius (Laying) 14 x OD mm 15 x OD mm Operating Temp.Range, min. - 5 °C -20 °C Operating Temp.Range, max. +60 °C +60 °C